Main entries ~3682 :
Date Id Summary Products Score Patch Annotated
2014-03-01 CVE-2014-1912 Buffer overflow in the socket.recvfrom_into function in Modules/socketmodule.c in Python 2.5 before 2.7.7, 3.x before 3.3.4, and 3.4.x before 3.4rc1 allows remote attackers to execute arbitrary code via a crafted string. Mac_os_x, Python N/A
2014-04-07 CVE-2014-0160 Heartbleed - The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. Symantec_messaging_gateway, Ubuntu_linux, Debian_linux, Fedora, Filezilla_server, V100_firmware, V60_firmware, Micollab, Mivoice, Openssl, Opensuse, Enterprise_linux_desktop, Enterprise_linux_server, Enterprise_linux_server_aus, Enterprise_linux_server_eus, Enterprise_linux_server_tus, Enterprise_linux_workstation, Gluster_storage, Storage, Virtualization, S9922l_firmware, Application_processing_engine_firmware, Cp_1543\-1_firmware, Elan\-8\.2, Simatic_s7\-1500_firmware, Simatic_s7\-1500t_firmware, Wincc_open_architecture, Splunk 7.5
2021-09-08 CVE-2021-40346 An integer overflow exists in HAProxy 2.0 through 2.5 in htx_add_header that can be exploited to perform an HTTP request smuggling attack, allowing an attacker to bypass all configured http-request HAProxy ACLs and possibly other ACLs. Haproxy, Haproxy_docker_image 7.5
2016-06-08 CVE-2016-5108 Buffer overflow in the DecodeAdpcmImaQT function in modules/codec/adpcm.c in VideoLAN VLC media player before 2.2.4 allows remote attackers to cause a denial of service (crash) or possibly execute arbitrary code via a crafted QuickTime IMA file. Debian_linux, Vlc_media_player 9.8
2017-06-01 CVE-2017-8386 git-shell did not correctly validate the given project path, allowing an argument injection which leads to arbitrary file reads and in some configurations command execution. Ubuntu_linux, Debian_linux, Fedora, Git\-Shell, Leap 8.8
2018-04-06 CVE-2018-1000156 GNU patch is processd by ed. This allows arbitrary command executions through a line beginning with ! Ubuntu_linux, Debian_linux, Patch, Enterprise_linux_desktop, Enterprise_linux_server, Enterprise_linux_server_aus, Enterprise_linux_server_eus, Enterprise_linux_server_tus, Enterprise_linux_workstation 7.8
2018-06-08 CVE-2018-4222 There is an out-of-bounds read when compiling WebAssembly source buffers in WebKit. If the buffer is a view, the offset is added to the buffer twice before this is copied. This could allow memory off the heap to be read out of the source buffer, either though parsing exceptions or data sections when they are copied Icloud, Iphone_os, Itunes, Safari, Tvos, Watchos, Ubuntu_linux 8.8
Remaining NVD entries (unprocessed / no code available): ~297333 :
Date Id Summary Products Score Patch
2020-06-29 CVE-2020-12036 Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. Prismaflex_firmware, Prismax_firmware N/A
2020-06-29 CVE-2020-12035 Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration. Prismaflex_firmware, Prismax_firmware N/A
2020-06-29 CVE-2020-12040 Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack. Sigma_spectrum_infusion_system_firmware N/A
2020-06-29 CVE-2020-12039 Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. Sigma_spectrum_infusion_system_firmware N/A
2020-06-29 CVE-2020-12047 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. Sigma_spectrum_infusion_system_firmware N/A
2020-06-29 CVE-2020-12045 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. Sigma_spectrum_infusion_system_firmware N/A
2020-06-29 CVE-2020-12043 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. Sigma_spectrum_infusion_system_firmware N/A