Main entries ~3682 :
Date Id Summary Products Score Patch Annotated
2014-03-01 CVE-2014-1912 Buffer overflow in the socket.recvfrom_into function in Modules/socketmodule.c in Python 2.5 before 2.7.7, 3.x before 3.3.4, and 3.4.x before 3.4rc1 allows remote attackers to execute arbitrary code via a crafted string. Mac_os_x, Python N/A
2014-04-07 CVE-2014-0160 Heartbleed - The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. Symantec_messaging_gateway, Ubuntu_linux, Debian_linux, Fedora, Filezilla_server, V100_firmware, V60_firmware, Micollab, Mivoice, Openssl, Opensuse, Enterprise_linux_desktop, Enterprise_linux_server, Enterprise_linux_server_aus, Enterprise_linux_server_eus, Enterprise_linux_server_tus, Enterprise_linux_workstation, Gluster_storage, Storage, Virtualization, S9922l_firmware, Application_processing_engine_firmware, Cp_1543\-1_firmware, Elan\-8\.2, Simatic_s7\-1500_firmware, Simatic_s7\-1500t_firmware, Wincc_open_architecture, Splunk 7.5
2021-09-08 CVE-2021-40346 An integer overflow exists in HAProxy 2.0 through 2.5 in htx_add_header that can be exploited to perform an HTTP request smuggling attack, allowing an attacker to bypass all configured http-request HAProxy ACLs and possibly other ACLs. Haproxy, Haproxy_docker_image 7.5
2016-06-08 CVE-2016-5108 Buffer overflow in the DecodeAdpcmImaQT function in modules/codec/adpcm.c in VideoLAN VLC media player before 2.2.4 allows remote attackers to cause a denial of service (crash) or possibly execute arbitrary code via a crafted QuickTime IMA file. Debian_linux, Vlc_media_player 9.8
2017-06-01 CVE-2017-8386 git-shell did not correctly validate the given project path, allowing an argument injection which leads to arbitrary file reads and in some configurations command execution. Ubuntu_linux, Debian_linux, Fedora, Git\-Shell, Leap 8.8
2018-04-06 CVE-2018-1000156 GNU patch is processd by ed. This allows arbitrary command executions through a line beginning with ! Ubuntu_linux, Debian_linux, Patch, Enterprise_linux_desktop, Enterprise_linux_server, Enterprise_linux_server_aus, Enterprise_linux_server_eus, Enterprise_linux_server_tus, Enterprise_linux_workstation 7.8
2018-06-08 CVE-2018-4222 There is an out-of-bounds read when compiling WebAssembly source buffers in WebKit. If the buffer is a view, the offset is added to the buffer twice before this is copied. This could allow memory off the heap to be read out of the source buffer, either though parsing exceptions or data sections when they are copied Icloud, Iphone_os, Itunes, Safari, Tvos, Watchos, Ubuntu_linux 8.8
Remaining NVD entries (unprocessed / no code available): ~294834 :
Date Id Summary Products Score Patch
2020-12-01 CVE-2020-25181 WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary code execution. Plc_editor 8.8
2020-12-01 CVE-2020-26762 A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08. Ic\-3116w_firmware, Ic\-3140w_firmware 9.8
2020-12-01 CVE-2020-7545 A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage. Ecostruxure_energy_expert, Ecostruxure_power_monitoring_expert, Power_manager, Powerscada_expert_with_advanced_reporting_and_dashboards, Powerscada_operation_with_advanced_reporting_and_dashboards 7.2
2020-12-01 CVE-2020-7546 A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage. Ecostruxure_energy_expert, Ecostruxure_power_monitoring_expert, Power_manager, Powerscada_expert_with_advanced_reporting_and_dashboards, Powerscada_operation_with_advanced_reporting_and_dashboards 5.4
2020-12-01 CVE-2020-7547 A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level. Ecostruxure_energy_expert, Ecostruxure_power_monitoring_expert, Power_manager, Powerscada_expert_with_advanced_reporting_and_dashboards, Powerscada_operation_with_advanced_reporting_and_dashboards 8.8
2020-12-01 CVE-2020-7548 A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login. Acti9_powertag_link_firmware, Acti9_powertag_link_hd_firmware, Acti9_smartlink_el_b_firmware, Acti9_smartlink_si_b_firmware, Acti9_smartlink_si_d_firmware, Wiser_energy_firmware, Wiser_link_firmware 9.8
2020-12-01 CVE-2020-4128 HCL Domino is susceptible to a lockout policy bypass vulnerability in the ID Vault service. An unauthenticated attacker could use this vulnerability to mount a brute force attack against the ID Vault service. Domino 5.3