Product:

Tx9_pro_firmware

(Tenda)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 9
Date Id Summary Products Score Patch Annotated
2024-04-24 CVE-2024-4111 A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tx9_pro_firmware 8.8
2024-04-24 CVE-2024-4112 A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tx9_pro_firmware 8.8
2024-04-24 CVE-2024-4113 A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tx9_pro_firmware 8.8
2024-04-24 CVE-2024-4114 A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tx9_pro_firmware 8.8
2022-05-05 CVE-2022-29592 Tenda TX9 Pro 22.03.02.10 devices allow OS command injection via set_route (called by doSystemCmd_route). Tx9_pro_firmware 9.8
2022-05-10 CVE-2022-29591 Tenda TX9 Pro 22.03.02.10 devices have a SetNetControlList buffer overflow. Tx9_pro_firmware 9.8
2022-05-18 CVE-2022-30033 Tenda TX9 Pro V22.03.02.10 is vulnerable to Buffer Overflow via the functtion setIPv6Status() in httpd module. Tx9_pro_firmware 7.5
2022-08-29 CVE-2022-38510 Tenda_TX9pro V22.03.02.10 was discovered to contain a buffer overflow via the component httpd/SetNetControlList. Tx9_pro_firmware 7.8
2022-11-30 CVE-2022-45337 Tenda TX9 Pro v22.03.02.10 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind. Tx9_pro_firmware 7.5