Note:
This project will be discontinued after December 13, 2021. [more]
Product:
Ac7_firmware
(Tenda)Repositories |
Unknown: This might be proprietary software. |
#Vulnerabilities | 51 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2024-03-26 | CVE-2024-2901 | A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | Ac7_firmware | 8.8 | ||
2024-03-26 | CVE-2024-2902 | A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | Ac7_firmware | 8.8 | ||
2024-03-26 | CVE-2024-2903 | A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not... | Ac7_firmware | 8.8 | ||
2023-07-14 | CVE-2023-37714 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic. | Ac7_firmware, F1202_firmware, Fh1202_firmware, Pw201a_firmware | 9.8 | ||
2023-07-14 | CVE-2023-37716 | Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | Ac10_firmware, Ac1206_firmware, Ac5_firmware, Ac7_firmware, Ac9_firmware, F1202_firmware, Fh1202_firmware | 9.8 | ||
2023-07-14 | CVE-2023-37717 | Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | Ac10_firmware, Ac1206_firmware, Ac5_firmware, Ac7_firmware, Ac9_firmware, F1202_firmware, Fh1202_firmware | 9.8 | ||
2023-08-07 | CVE-2023-38931 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. | Ac10_firmware, Ac1206_firmware, Ac5_firmware, Ac6_firmware, Ac7_firmware, Ac8_firmware, F1203_firmware, Fh1203_firmware | 9.8 | ||
2023-08-07 | CVE-2023-38930 | Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. | Ac5_firmware, Ac7_firmware, Ac9_firmware, F1203_firmware, Fh1205_firmware | 9.8 | ||
2023-08-07 | CVE-2023-38933 | Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | Ac10_firmware, Ac1206_firmware, Ac5_firmware, Ac6_firmware, Ac7_firmware, Ac9_firmware, F1203_firmware, Fh1203_firmware, Fh1205_firmware | 9.8 | ||
2023-08-07 | CVE-2023-38936 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | Ac10_firmware, Ac1206_firmware, Ac5_firmware, Ac6_firmware, Ac7_firmware, Ac9_firmware, F1203_firmware, Fh1203_firmware, Fh1205_firmware | 9.8 |