Product:

Ac5_firmware

(Tenda)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 29
Date Id Summary Products Score Patch Annotated
2022-01-28 CVE-2021-44971 Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE. Ac15_firmware, Ac5_firmware 9.8
2023-08-30 CVE-2023-41562 Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. Ac5_firmware, Ac7_firmware, Ac9_firmware 9.8
2023-08-30 CVE-2023-41561 Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. Ac5_firmware, Ac9_firmware 9.8
2023-08-30 CVE-2023-41559 Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. Ac5_firmware, Ac7_firmware, Ac9_firmware 9.8
2023-08-30 CVE-2023-41563 Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. Ac5_firmware, Ac9_firmware 9.8
2023-08-30 CVE-2023-41553 Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. Ac5_firmware, Ac9_firmware 9.8
2023-08-30 CVE-2023-41556 Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. Ac5_firmware, Ac7_firmware, Ac9_firmware 9.8
2023-08-30 CVE-2023-41557 Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. Ac5_firmware, Ac7_firmware 9.8
2023-08-07 CVE-2023-38933 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. Ac10_firmware, Ac1206_firmware, Ac5_firmware, Ac6_firmware, Ac7_firmware, Ac9_firmware, F1203_firmware, Fh1203_firmware, Fh1205_firmware 9.8
2023-08-07 CVE-2023-38931 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. Ac10_firmware, Ac1206_firmware, Ac5_firmware, Ac6_firmware, Ac7_firmware, Ac8_firmware, F1203_firmware, Fh1203_firmware 9.8