Note:
This project will be discontinued after December 13, 2021. [more]
Product:
Ac500_firmware
(Tenda)Repositories |
Unknown: This might be proprietary software. |
#Vulnerabilities | 14 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2024-04-17 | CVE-2024-32314 | Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. | Ac500_firmware | N/A | ||
2024-04-17 | CVE-2024-32316 | Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. | Ac500_firmware | N/A | ||
2024-04-17 | CVE-2024-32318 | Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function. | Ac500_firmware | N/A | ||
2024-04-17 | CVE-2024-32320 | Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function. | Ac500_firmware | N/A | ||
2023-02-27 | CVE-2023-25234 | Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface. | Ac500_firmware | 9.8 | ||
2023-02-27 | CVE-2023-25233 | Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface. | Ac500_firmware | 9.8 | ||
2023-02-27 | CVE-2023-25235 | Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid. | Ac500_firmware | 7.5 | ||
2024-04-17 | CVE-2024-3909 | A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | Ac500_firmware | 9.8 | ||
2024-04-17 | CVE-2024-3905 | A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not... | Ac500_firmware | 8.8 | ||
2024-04-17 | CVE-2024-3906 | A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not... | Ac500_firmware | 8.8 |