Note:
This project will be discontinued after December 13, 2021. [more]
Product:
Powerlogic_ion8650_firmware
(Schneider\-Electric)Repositories |
Unknown: This might be proprietary software. |
#Vulnerabilities | 5 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2021-02-19 | CVE-2021-22703 | A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device. | Powerlogic_ion7400_firmware, Powerlogic_ion7650_firmware, Powerlogic_ion8300_firmware, Powerlogic_ion8400_firmware, Powerlogic_ion8500_firmware, Powerlogic_ion8600_firmware, Powerlogic_ion8650_firmware, Powerlogic_ion8800_firmware, Powerlogic_ion9000_firmware, Powerlogic_pm8000_firmware | 7.5 | ||
2021-02-19 | CVE-2021-22701 | A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface. | Powerlogic_ion7400_firmware, Powerlogic_ion7650_firmware, Powerlogic_ion8300_firmware, Powerlogic_ion8400_firmware, Powerlogic_ion8500_firmware, Powerlogic_ion8600_firmware, Powerlogic_ion8650_firmware, Powerlogic_ion8800_firmware, Powerlogic_ion9000_firmware, Powerlogic_pm8000_firmware | 4.5 | ||
2021-02-19 | CVE-2021-22702 | A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device. | Powerlogic_ion7300_firmware, Powerlogic_ion7400_firmware, Powerlogic_ion7650_firmware, Powerlogic_ion7700_firmware, Powerlogic_ion8300_firmware, Powerlogic_ion8400_firmware, Powerlogic_ion8500_firmware, Powerlogic_ion8600_firmware, Powerlogic_ion8650_firmware, Powerlogic_ion8800_firmware, Powerlogic_ion9000_firmware, Powerlogic_pm8000_firmware | 7.5 | ||
2021-03-11 | CVE-2021-22713 | A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot. | Ion7650_firmware, Powerlogic_ion7300_firmware, Powerlogic_ion7550_firmware, Powerlogic_ion7650_firmware, Powerlogic_ion7700_firmware, Powerlogic_ion8300_firmware, Powerlogic_ion8400_firmware, Powerlogic_ion8500_firmware, Powerlogic_ion8600_firmware, Powerlogic_ion8650_firmware, Powerlogic_ion8800_firmware | 7.5 | ||
2023-05-22 | CVE-2022-46680 | A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic. | Powerlogic_ion7400_firmware, Powerlogic_ion8650_firmware, Powerlogic_ion8800_firmware, Powerlogic_ion9000_firmware, Powerlogic_pm8000_firmware | 9.8 |