Product:

Gx_works3

(Mitsubishielectric)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 33
Date Id Summary Products Score Patch Annotated
2022-05-19 CVE-2020-14496 Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Em_configurator, Ezsocket, Fr_configurator2, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsoft_fielddeviceconfigurator, Melsoft_navigator, Mh11_settingtool_version2, Motorizer, Mr_configurator2, Mt_works2, Mx_component, Network_interface_board_cc\-Link_ver\.2_utility, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3 9.8
2022-11-25 CVE-2022-25164 Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module. Gx_works3, Mx_opc_ua_module_configurator\-R 7.5
2022-11-25 CVE-2022-29825 Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. Gx_works3 7.5
2022-11-25 CVE-2022-29826 Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. Gx_works3 7.5
2022-11-25 CVE-2022-29828 Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally. Gx_works3 7.5
2022-11-25 CVE-2022-29827 Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally. Gx_works3 7.5
2022-11-25 CVE-2022-29829 Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. Gx_works3 7.5
2022-11-25 CVE-2022-29830 Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally. Gx_works3 9.1
2022-11-25 CVE-2022-29832 Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting. Gx_works3 6.5
2022-11-25 CVE-2022-29831 Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules. Gx_works3 7.5