Product:

Gt_designer3

(Mitsubishielectric)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 7
Date Id Summary Products Score Patch Annotated
2022-02-11 CVE-2020-14521 Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. C_controller_interface_module_utility, C_controller_module_setting_and_monitoring_tool, Cc\-Link_ie_control_network_data_collector, Cc\-Link_ie_field_network_data_collector, Cc\-Link_ie_tsn_data_collector, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator2, Fr_configurator_sw3, Gt_designer2_classic, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_developer, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_complete_clean_up_tool, Melsoft_em_software_development_kit, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Motion_control_setting, Motorizer, Mr_configurator2, Mt_works2, Mtconnect_data_collector, Mx_component, Mx_mesinterface, Mx_mesinterface\-R, Mx_sheet, Network_interface_board_cc\-Link_ver\.2_utility_firmware, Network_interface_board_cc_ie_control_utility_firmware, Network_interface_board_cc_ie_field_utility_firmware, Network_interface_board_mneth_utility_firmware, Position_board_utility_2, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector 9.8
2021-02-19 CVE-2021-20588 Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000)... C_controller_module_setting_and_monitoring_tool, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator, Fr_configurator2, Fr_configurator_sw3, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_configurator\-Dp, Gx_configurator\-Qp, Gx_developer, Gx_explorer, Gx_iec_developer, Gx_logviewer, Gx_remoteservice\-I, Gx_works2, Gx_works3, Iq_monozukuri_andon, Iq_monozukuri_process_remote_monitoring, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_em_software_development_kit, Melsoft_navigator, Mh11_settingtool_version2, Mi_configurator, Mt_works2, Mx_component, Network_interface_board_cc\-Link, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector 9.8
2023-08-04 CVE-2023-0525 Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated... Gs21_firmware, Gs25_firmware, Gt21_firmware, Gt23_firmware, Gt25_firmware, Gt27_firmware, Gt_designer3, Gt_softgot2000 7.5
2021-02-19 CVE-2021-20587 Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT... C_controller_module_setting_and_monitoring_tool, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator, Fr_configurator2, Fr_configurator_sw3, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_configurator\-Dp, Gx_configurator\-Qp, Gx_developer, Gx_explorer, Gx_iec_developer, Gx_logviewer, Gx_remoteservice\-I, Gx_works2, Gx_works3, Iq_monozukuri_andon, Iq_monozukuri_process_remote_monitoring, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_em_software_development_kit, Melsoft_navigator, Mh11_settingtool_version2, Mi_configurator, Mt_works2, Mx_component, Network_interface_board_cc\-Link, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector 9.8
2022-05-19 CVE-2020-14496 Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Em_configurator, Ezsocket, Fr_configurator2, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsoft_fielddeviceconfigurator, Melsoft_navigator, Mh11_settingtool_version2, Motorizer, Mr_configurator2, Mt_works2, Mx_component, Network_interface_board_cc\-Link_ver\.2_utility, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3 9.8
2020-06-30 CVE-2020-5602 Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible... Cpu_module_logging_configuration_tool, Cw_configurator, Em_configurator, Gt_designer3, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec\-L_flexible_high\-Speed_i\/o_control_module_configuration_tool, Melsoft_fielddeviceconfigurator, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Motion_control_setting, Mr_configurator2, Mt_works2, Rt_toolbox2, Rt_toolbox3 N/A
2020-06-30 CVE-2020-5603 Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier,... Cpu_module_logging_configuration_tool, Cw_configurator, Em_configurator, Gt_designer3, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec\-L_flexible_high\-Speed_i\/o_control_module_configuration_tool, Melsoft_fielddeviceconfigurator, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Motion_control_setting, Mr_configurator2, Mt_works2, Rt_toolbox2, Rt_toolbox3 N/A