Product:

W30e_firmware

(Tenda)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 45
Date Id Summary Products Score Patch Annotated
2024-04-16 CVE-2024-3880 A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. W30e_firmware 8.8
2024-04-16 CVE-2024-3881 A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. W30e_firmware 8.8
2024-04-16 CVE-2024-3882 A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. W30e_firmware 8.8
2022-12-08 CVE-2022-45505 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand. W30e_firmware 7.5
2022-12-08 CVE-2022-45506 Tenda W30E v1.0.1.25(633) was discovered to contain a command injection vulnerability via the fileNameMit parameter at /goform/delFileName. W30e_firmware 9.8
2022-12-08 CVE-2022-45507 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName. W30e_firmware 7.5
2022-12-08 CVE-2022-45508 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the new_account parameter at /goform/editUserName. W30e_firmware 7.5
2022-12-08 CVE-2022-45509 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. W30e_firmware 7.5
2022-12-08 CVE-2022-45510 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the mit_ssid_index parameter at /goform/AdvSetWrlsafeset. W30e_firmware 7.5
2022-12-08 CVE-2022-45511 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex. W30e_firmware 7.5