Note:
This project will be discontinued after December 13, 2021. [more]
Product:
Stormshield_network_security
(Stormshield)Repositories |
Unknown: This might be proprietary software. |
#Vulnerabilities | 35 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2023-02-08 | CVE-2022-4304 | A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master... | Openssl, Endpoint_security, Sslvpn, Stormshield_network_security | 5.9 | ||
2023-02-08 | CVE-2023-0286 | There is a type confusion vulnerability relating to X.400 address processing inside an X.509 GeneralName. X.400 addresses were parsed as an ASN1_STRING but the public structure definition for GENERAL_NAME incorrectly specified the type of the x400Address field as ASN1_TYPE. This field is subsequently interpreted by the OpenSSL function GENERAL_NAME_cmp as an ASN1_TYPE rather than an ASN1_STRING. When CRL checking is enabled (i.e. the application sets the X509_V_FLAG_CRL_CHECK flag), this... | Openssl, Stormshield_management_center, Stormshield_network_security | 7.4 | ||
2024-02-29 | CVE-2023-34198 | In Stormshield Network Security (SNS) 1.0.0 through 3.7.36 before 3.7.37, 3.8.0 through 3.11.24 before 3.11.25, 4.0.0 through 4.3.18 before 4.3.19, 4.4.0 through 4.6.5 before 4.6.6, and 4.7.0 before 4.7.1, the usage of a Network object created from an inactive DHCP interface in the filtering slot results in the usage of an object of the :any" type, which may have unexpected results for access control. | Stormshield_network_security | 7.3 | ||
2024-02-29 | CVE-2023-41165 | An issue was discovered in Stormshield Network Security (SNS) 3.7.0 through 3.7.38 before 3.7.39, 3.10.0 through 3.11.26 before 3.11.27, 4.0 through 4.3.21 before 4.3.22, and 4.4.0 through 4.6.8 before 4.6.9. An administrator with write access to the SNS firewall can configure a login disclaimer with malicious JavaScript elements that can result in data theft. | Stormshield_network_security | 4.8 | ||
2020-04-13 | CVE-2020-8430 | Stormshield Network Security 310 3.7.10 devices have an auth/lang.html?rurl= Open Redirect vulnerability on the captive portal. For example, the attacker can use rurl=//example.com instead of rurl=https://example.com in the query string. | Stormshield_network_security | 6.1 | ||
2020-10-06 | CVE-2020-7465 | The L2TP implementation of MPD before 5.9 allows a remote attacker who can send specifically crafted L2TP control packet with AVP Q.931 Cause Code to execute arbitrary code or cause a denial of service (memory corruption). | Mpd, Stormshield_network_security | 9.8 | ||
2020-10-06 | CVE-2020-7466 | The PPP implementation of MPD before 5.9 allows a remote attacker who can send specifically crafted PPP authentication message to cause the daemon to read beyond allocated memory buffer, which would result in a denial of service condition. | Mpd, Stormshield_network_security | 7.5 | ||
2021-03-02 | CVE-2021-3384 | A vulnerability in Stormshield Network Security could allow an attacker to trigger a protection related to ARP/NDP tables management, which would temporarily prevent the system to contact new hosts via IPv4 or IPv6. This affects versions 2.0.0 to 2.7.7, 2.8.0 to 2.16.0, 3.0.0 to 3.7.16, 3.8.0 to 3.11.4, and 4.0.0 to 4.1.5. Fixed in versions 2.7.8, 3.7.17, 3.11.5, and 4.2.0. | Stormshield_network_security | 5.3 | ||
2021-03-19 | CVE-2021-27506 | The ClamAV Engine (version 0.103.1 and below) component embedded in Storsmshield Network Security (SNS) is subject to DoS in case of parsing of malformed png files. This affect Netasq versions 9.1.0 to 9.1.11 and SNS versions 1.0.0 to 4.2.0. This issue is fixed in SNS 3.7.19, 3.11.7 and 4.2.1. | Clamav, Netasq, Stormshield_network_security | 5.5 | ||
2021-05-06 | CVE-2021-28665 | Stormshield SNS with versions before 3.7.18, 3.11.6 and 4.1.6 has a memory-management defect in the SNMP plugin that can lead to excessive consumption of memory and CPU resources, and possibly a denial of service. | Network_security, Stormshield_network_security | 7.5 |