2022-02-09 CVE-2021-40363 A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected... Simatic_pcs_7, Simatic_wincc 7.8
2021-08-27 CVE-2021-40142 In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer. Local_discover_server, Simatic_net_pc, Simatic_process_historian_opc_ua_server_firmware, Simatic_wincc, Simatic_wincc_runtime, Simatic_wincc_unified_scada_runtime, Telecontrol_server_basic 7.5
2019-08-13 CVE-2019-10929 A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0),... Simatic_cp_1626_firmware, Simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware, Simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware, Simatic_hmi_panel_firmware, Simatic_net_pc, Simatic_s7\-1200_cpu_1211c_firmware, Simatic_s7\-1200_cpu_1212c_firmware, Simatic_s7\-1200_cpu_1214c_firmware, Simatic_s7\-1200_cpu_1215c_firmware, Simatic_s7\-1200_cpu_1217c_firmware, Simatic_s7\-1500, Simatic_s7\-1500_cpu_1511c_firmware, Simatic_s7\-1500_cpu_1512c_firmware, Simatic_s7\-1500_cpu_1518_firmware, Simatic_s7\-Plcsim_advanced, Simatic_step_7, Simatic_tim_1531_irc_firmware, Simatic_wincc, Simatic_wincc_open_architecture, Simatic_wincc_runtime 5.9
2017-11-06 CVE-2017-14023 An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. Simatic_pcs7, Simatic_wincc 4.9
2019-05-14 CVE-2019-10917 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime... Simatic_pcs_7, Simatic_wincc, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime_professional 5.5
2019-05-14 CVE-2019-10918 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime... Simatic_pcs_7, Simatic_wincc, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime_professional 8.8
2019-05-14 CVE-2019-10916 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime... Simatic_pcs_7, Simatic_wincc, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime_professional 8.8
2021-02-09 CVE-2020-10048 A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication. Simatic_pcs_7, Simatic_wincc 5.5
2019-07-11 CVE-2019-10935 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions <... Simatic_pcs_7, Simatic_wincc, Simatic_wincc_runtime 7.2
2019-05-14 CVE-2019-10922 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No... Simatic_pcs_7, Simatic_wincc 9.8