2024-12-10 | CVE-2024-10494 | An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions. | Labview | 7.8 | ||
2024-12-10 | CVE-2024-10495 | An out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions. | Labview | 7.8 | ||
2024-12-10 | CVE-2024-10496 | An out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions. | Labview | 7.8 | ||
2024-03-11 | CVE-2024-23610 | An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | Labview | 7.8 | ||
2024-03-11 | CVE-2024-23611 | An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | Labview | 7.8 | ||
2022-04-21 | CVE-2022-27237 | There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later. | Flexlogger, G_web_development_software, Labview, Static_test_software_suite, Systemlink | 6.1 | ||
2024-07-23 | CVE-2024-4079 | An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | Labview | 7.8 | ||
2024-07-23 | CVE-2024-4081 | A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions. | Labview | 7.8 | ||
2024-07-23 | CVE-2024-4080 | A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | Labview | 7.8 | ||
2013-08-06 | CVE-2013-5021 | Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX... | Datamanager, Labview, Labwindows, Measurementstudio, Teststand | N/A |