Note:
This project will be discontinued after December 13, 2021. [more]
Product:
Junos
(Juniper)Repositories |
• https://github.com/embedthis/appweb
• https://github.com/jquery/jquery-ui |
#Vulnerabilities | 647 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2020-10-16 | CVE-2020-1680 | On Juniper Networks MX Series with MS-MIC or MS-MPC card configured with NAT64 configuration, receipt of a malformed IPv6 packet may crash the MS-PIC component on MS-MIC or MS-MPC. This issue occurs when a multiservice card is translating the malformed IPv6 packet to IPv4 packet. An unauthenticated attacker can continuously send crafted IPv6 packets through the device causing repetitive MS-PIC process crashes, resulting in an extended Denial of Service condition. This issue affects Juniper... | Junos | N/A | ||
2020-10-16 | CVE-2020-1656 | The DHCPv6 Relay-Agent service, part of the Juniper Enhanced jdhcpd daemon shipped with Juniper Networks Junos OS has an Improper Input Validation vulnerability which will result in a Denial of Service (DoS) condition when a DHCPv6 client sends a specific DHPCv6 message allowing an attacker to potentially perform a Remote Code Execution (RCE) attack on the target device. Continuous receipt of the specific DHCPv6 client message will result in an extended Denial of Service (DoS) condition. If... | Junos | N/A | ||
2020-10-16 | CVE-2020-1665 | On Juniper Networks MX Series and EX9200 Series, in a certain condition the IPv6 Distributed Denial of Service (DDoS) protection might not take affect when it reaches the threshold condition. The DDoS protection allows the device to continue to function while it is under DDoS attack, protecting both the Routing Engine (RE) and the Flexible PIC Concentrator (FPC) during the DDoS attack. When this issue occurs, the RE and/or the FPC can become overwhelmed, which could disrupt network protocol... | Junos | N/A | ||
2020-10-16 | CVE-2020-1679 | On Juniper Networks PTX and QFX Series devices with packet sampling configured using tunnel-observation mpls-over-udp, sampling of a malformed packet can cause the Kernel Routing Table (KRT) queue to become stuck. KRT is the module within the Routing Process Daemon (RPD) that synchronized the routing tables with the forwarding tables in the kernel. This table is then synchronized to the Packet Forwarding Engine (PFE) via the KRT queue. Thus, when KRT queue become stuck, it can lead to... | Junos | N/A | ||
2020-10-16 | CVE-2020-1657 | On SRX Series devices, a vulnerability in the key-management-daemon (kmd) daemon of Juniper Networks Junos OS allows an attacker to spoof packets targeted to IPSec peers before a security association (SA) is established thereby causing a failure to set up the IPSec channel. Sustained receipt of these spoofed packets can cause a sustained Denial of Service (DoS) condition. This issue affects IPv4 and IPv6 implementations. This issue affects Juniper Networks Junos OS on SRX Series: 12.3X48... | Junos | N/A | ||
2020-10-16 | CVE-2020-1660 | When DNS filtering is enabled on Juniper Networks Junos MX Series with one of the following cards MS-PIC, MS-MIC or MS-MPC, an incoming stream of packets processed by the Multiservices PIC Management Daemon (mspmand) process, responsible for managing "URL Filtering service", may crash, causing the Services PIC to restart. While the Services PIC is restarting, all PIC services including DNS filtering service (DNS sink holing) will be bypassed until the Services PIC completes its boot process.... | Junos | 9.9 | ||
2020-10-16 | CVE-2020-1662 | On Juniper Networks Junos OS and Junos OS Evolved devices, BGP session flapping can lead to a routing process daemon (RPD) crash and restart, limiting the attack surface to configured BGP peers. This issue only affects devices with BGP damping in combination with accepted-prefix-limit configuration. When the issue occurs the following messages will appear in the /var/log/messages: rpd[6046]: %DAEMON-4-BGP_PREFIX_THRESH_EXCEEDED: XXXX (External AS x): Configured maximum accepted prefix-limit... | Junos | N/A | ||
2020-10-16 | CVE-2020-1664 | A stack buffer overflow vulnerability in the device control daemon (DCD) on Juniper Networks Junos OS allows a low privilege local user to create a Denial of Service (DoS) against the daemon or execute arbitrary code in the system with root privilege. This issue affects Juniper Networks Junos OS: 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.2X75 versions prior to 18.2X75-D53,... | Junos | N/A | ||
2020-10-16 | CVE-2020-1667 | When DNS filtering is enabled on Juniper Networks Junos MX Series with one of the following cards MS-PIC, MS-MIC or MS-MPC, an incoming stream of packets processed by the Multiservices PIC Management Daemon (mspmand) process might be bypassed due to a race condition. Due to this vulnerability, mspmand process, responsible for managing "URL Filtering service", can crash, causing the Services PIC to restart. While the Services PIC is restarting, all PIC services including DNS filtering service... | Junos | N/A | ||
2020-10-16 | CVE-2020-1668 | On Juniper Networks EX2300 Series, receipt of a stream of specific multicast packets by the layer2 interface can cause high CPU load, which could lead to traffic interruption. This issue occurs when multicast packets are received by the layer 2 interface. To check if the device has high CPU load due to this issue, the administrator can issue the following command: user@host> show chassis routing-engine Routing Engine status: ... Idle 2 percent the "Idle" value shows as low (2 % in the... | Junos | N/A |