Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2022-12-07 | CVE-2022-2002 | GE CIMPICITY versions 2022 and prior is vulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. | Cimplicity | 7.8 | ||
2022-12-07 | CVE-2022-2952 | GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. | Cimplicity | 7.8 | ||
2022-12-08 | CVE-2022-3084 | GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiRootOptionTable, which could allow an attacker to execute arbitrary code. | Cimplicity | 7.8 | ||
2022-12-08 | CVE-2022-3092 | GE CIMPICITY versions 2022 and prior is vulnerable to an out-of-bounds write, which could allow an attacker to execute arbitrary code. | Cimplicity | 7.8 | ||
2022-12-07 | CVE-2022-2948 | GE CIMPICITY versions 2022 and prior is vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code. | Cimplicity | 7.8 | ||
2023-07-19 | CVE-2023-3463 | All versions of GE Digital CIMPLICITY that are not adhering to SDG guidance and accepting documents from untrusted sources are vulnerable to memory corruption issues due to insufficient input validation, including issues such as out-of-bounds reads and writes, use-after-free, stack-based buffer overflows, uninitialized pointers, and a heap-based buffer overflow. Successful exploitation could allow an attacker to execute arbitrary code. | Cimplicity | 9.8 | ||
2023-09-05 | CVE-2023-4487 | GE CIMPLICITY 2023 is by a process control vulnerability, which could allow a local attacker to insert malicious configuration files in the expected web server execution path to escalate privileges and gain full control of the HMI software. | Cimplicity | 7.8 | ||
2016-07-15 | CVE-2016-5787 | General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors. | Cimplicity | 6.3 | ||
2017-02-13 | CVE-2016-9360 | An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session. | Cimplicity, Historian, Ifix | 6.7 | ||
2018-12-07 | CVE-2018-15362 | XXE in GE Proficy Cimplicity GDS versions 9.0 R2, 9.5, 10.0 | Cimplicity | 9.1 |