Unknown: This might be proprietary software. |
#Vulnerabilities | 31 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2022-10-31 | CVE-2022-41688 | Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group. | Infrasuite_device_master | 7.5 | ||
2023-01-13 | CVE-2022-41778 | Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. | Infrasuite_device_master | 8.8 | ||
2023-01-26 | CVE-2023-0444 | A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator. | Infrasuite_device_master | 8.8 | ||
2023-03-27 | CVE-2023-1133 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code. | Infrasuite_device_master | 9.8 | ||
2023-03-27 | CVE-2023-1134 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges. | Infrasuite_device_master | 8.8 | ||
2023-03-27 | CVE-2023-1143 | In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code. | Infrasuite_device_master | 8.8 | ||
2023-03-27 | CVE-2023-1144 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. | Infrasuite_device_master | 8.8 | ||
2023-03-27 | CVE-2023-1137 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation. | Infrasuite_device_master | 8.8 | ||
2023-03-27 | CVE-2023-1145 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution. | Infrasuite_device_master | 7.8 | ||
2023-03-27 | CVE-2023-1135 | In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation. | Infrasuite_device_master | 7.8 |